Hydraulic Starting system for E-genset

For this project two skid mounted hydraulic start system have been successfully tested and delivered. The system comprises 3x50 Liter accumulators designed according to ASMEVIII Div 1, U-stamped, certified by ABS and meant as a back up start system for a diesel driven emergency generator on board of a FPSO. 

The system pressure control philosophy is based on a start system control panel, pressure controlled by a pressure switch and auto mode function that automatically maintains the system at operation pressure. Engine start attempts are manually initiated by means of a hand operated valve.  

The design, construction, and testing, including performance testing to Hatraco and EPC standards, are all conducted in-house.


 

TECHNICAL INFORMATION
Project:Almirante Barroso MV32 FPSO
End user:Petrobras
Location:Brazil, Buzios field
EPCC:Modec
Start capacity:3x50 Litre
Start requirements :3 times, 5 seconds each
Recharge time:within 15-20 minutes
Engine:Cummins QSK60
Required engine firing speed  :150 RPM
Application:Back up start system for a Cummins QSK60 diesel driven E-genset
Design code / Certification   :ABS certied Accumulators, Compliant with Brazilian NR 13 regulation