For a special project in the Kinh Ngu Trang/Kinh Ngu Trang Nam (KNT/KTN) Oil and Gas Field in Vietnam, Hatraco has been awarded a tender to design and supply 2 hydraulic starting systems which will be used a s a secondary start system for a emergency diesel generators. These Cummins QSK60 diesel driven generators will provide back-up power on board of offshore drilling and supply platforms in the oil and gas fields in case of black out situation. 1 hydraulic start systems is completely accomodated with EX (d) zone 1/2 electric components and mechanical instrumentation allowing it be operated in a zoned area. Both an electric driven recharge pump and a PTO driven recharge pump ensure a accumulator recharge cycle within 15 minutes of all 3 accumulators. The electric driven recharge pump is stand alone controlled by a pressure transmitter which signals the start system's control panel to cut in and out the pump and pre set system pressure and the systems.
TECHNICAL INFORMATION
Project | : | KNT-KTN |
End user | : | Vietnam Oil and Gas Group |
Location | : | Vietnam |
EPCC | : | PetroVietnam Exploration Production Corporation |
Start capacity | : | 3 x 50 Liter |
Start requirements | : | 3 times 8 seconds each |
Recharge time | : | Within 15 minutes |
Engine | : | Cummins QSK60 |
Required engine firing speed | : | 150 RPM |
Application | : | Cummins QSK60 driven E-gen |
Design code / Certification | : | Accumulator design according to ASME VIII Div 1 |
Specialties | : | EX (d) zone 1/2 electric components and mechanical instrumentation, |
Control panel, E-motor and PTO driven Recharge pump | ||
Centralized start valve manifold |